Cutting Motor Start Capacitor CBB60 70uF±5% 250VAC C SH P0 25/70/21 50/60Hz RU Capacitance Rating 70 uF Material Polypropylene Film Coated Plug 2 Terminal MPN CBB60-250V Minimum Operating Temperature -25 °C (-13 °F) Minimum Operating Voltage 250 V Capacitor Construction Metallized Polypropylene Film Tolerance Rating ±5 % Manufacturer Warranty 1 Month Maximum Operating Temperature 70 °C (158 °F) Resistance Rating N Maximum Operating Voltage 250 V Dia. 34 mm ,1.3 inch Height 60 mm, 2.4 inch (not including wires )
|
Cutting Motor Run Capacitor CBB60 30uF±5% 250VAC C SH S0 40/70/21 50/60Hz RU Capacitance Rating 30 uF Material Polypropylene Film Coated Plug 2 Terminal MPN CBB60-450V Minimum Operating Temperature -25 °C (-13 °F) Minimum Operating Voltage 450 V Capacitor Construction Metallized Polypropylene Film Tolerance Rating ±5 % Manufacturer Warranty 1 Month Maximum Operating Temperature 70 °C (158 °F) Resistance Rating N Maximum Operating Voltage 450 V Dia. 34 mm ,1.3 inch Height 60 mm, 2.4 inch (not including wires )
|
Clamp Motor Start Capacitor
Capacitance Rating 12 uF Material Polypropylene Plug 2 Pin Terminal MPN CBB61-500V Minimum Operating Temperature -25 °C (-13 °F) Minimum Operating Voltage 500 V Capacitor Construction Metallized Polypropylene Film Tolerance Rating ±5 % Manufacturer Warranty 1 Month Maximum Operating Temperature 70 °C (158 °F) Resistance Rating N Maximum Operating Voltage 500 V
|
|
|
|
|
|
|
|
|
|
|
|
|
Clamp Motor Start Capacitor
Capacitance Rating 30 uF Material Polypropylene Plug 2 Pin Terminal MPN CBB61W-250V Minimum Operating Temperature -25 °C (-13 °F) Minimum Operating Voltage 250 V Capacitor Construction Metallized Polypropylene Film Tolerance Rating ±5 % Manufacturer Warranty 1 Month Maximum Operating Temperature 70 °C (158 °F) Resistance Rating N Maximum Operating Voltage 250 V
|
Cutting Motor Start Capacitor CD60 200uF±15% 250VAC 50/60Hz 20/55/21 Capacitance Rating 200 uF Material aluminum shell, durable polypropylene film Plug 2 Terminal MPN CD60-250V Minimum Operating Temperature -25 °C (-13 °F) Minimum Operating Voltage 250 V Capacitor Construction Metallized Polypropylene Film Tolerance Rating ±5 % Manufacturer Warranty 1 Year Maximum Operating Temperature 70 °C (158 °F) Resistance Rating N Maximum Operating Voltage 250 V Size 4.33x1.97x1.97 Inches (not including the wire)
|
Clamp Motor Start Capacitor
Capacitance Rating 32 uF Material Polypropylene Plug 2 Pin Terminal MPN CBB61-250V Minimum Operating Temperature -25 °C (-13 °F) Minimum Operating Voltage 250 V Capacitor Construction Metallized Polypropylene Film Tolerance Rating ±5 % Manufacturer Warranty 1 Month Maximum Operating Temperature 70 °C (158 °F) Resistance Rating N Maximum Operating Voltage 250 V
|
|
|
|
|
|
|
|
|
|
|
|
|
Clamp Motor Start Capacitor
Capacitance Rating 35 uF Material Polypropylene Plug 2 Pin Terminal MPN CBB61-250V Minimum Operating Temperature -25 °C (-13 °F) Minimum Operating Voltage 250 V Capacitor Construction Metallized Polypropylene Film Tolerance Rating ±5 % Manufacturer Warranty 1 Month Maximum Operating Temperature 70 °C (158 °F) Resistance Rating N Maximum Operating Voltage 250 V
|
Clamp Motor Start Capacitor
Capacitance Rating 2.5 uF Material Polypropylene Plug 2 Pin Terminal MPN CBB61-450V Minimum Operating Temperature -25 °C (-13 °F) Minimum Operating Voltage 450 V Capacitor Construction Metallized Polypropylene Film Tolerance Rating ±5 % Manufacturer Warranty 1 Month Maximum Operating Temperature 70 °C (158 °F) Resistance Rating N Maximum Operating Voltage 450 V
|
OEM Emergency Push Button Stop Switch 110/220V
4 Terminal Contacts
|
|
|
|
|
|
|
|
|
|
|
|
|
Magnetic Clamp Timing Sensor (2 hole mount) 3 pin male plug (5om)
There is no returns, exchange or refunds on Electrical or Electronic Components.
|
Back Plate Distance Magnetic Sensor (2 hole mount) 3 pin male plug (3om)
There is no returns, exchange or refunds on Electrical or Electronic Components.
|
Magnetic Clamp Sensor LED Reader (2 hole mount) 3 pin (3om to 5om) Works on clamp or back plate rear position.
|
|
|
|
|
|
|
|
|
|
|
|
|
Cut Cycle Sensor (Flag Sensor) 3 pin plug in bottom mount There are no returns, exchanges or refunds on electrical or electronic parts.
|
Cut Cycle Sensor (Flag Sensor) 3 pin plug in from side or bottom There are no returns, exchanges or refunds on electrical or electronic parts.
|
Cut Cycle Sensor (Flag Sensor) 4 pin plug in from side or bottom There are no returns, exchanges or refunds on electrical or electronic parts.
|
|
|
|
|
|
|
|
|
|
|
|
|
Emergency Stop Button
10 Amp 22mm Latching, Push Button Switch, Aluminum Alloy Round Emergency Stop Switch, IP65 Waterproof Self-Locking E Stop Emergency Shut Off Switch, 1NO 1NC 110/220/440V (Type A) NEMA Rated
|
Cut Button Set of 2 Internal Switch (single contact 2 post)
|
Cut Button Set of 2 Internal Switch (single contact 2 post)
|
|
|
|
|
|
|
|
|
|
|
|
|
OEM Cut Button, 4 back terminal contacts. 2 Button Set
|
IR Safety Wall Control Board 4606S Please match your board up exactly with the photograph.
Different manufacture's of the same item name use different boards.
Even the same manufacturer's use different boards as the machine develops.
Example: Last years board may be different from this years board for the same machine.
If the machine name matches but the board is different contact us.
We probably have it in stock.
We have no return on electronic parts.
|
IR Safety Wall Control Board 4606, 4608 R-K Please match your board up exactly with the photograph.
Different manufacture's of the same item name use different boards.
Even the same manufacturer's use different boards as the machine develops.
Example: Last years board may be different from this years board for the same machine.
If the machine name matches but the board is different contact us.
We probably have it in stock.
We have no return on electronic parts.
|
|
|
|
|
|
|
|
|
|
|
|
|
DK Amperage Reader This reader is the first in its class designed to double the life of your paper cutter. Knowing when your cutter is working extremely hard cutting paper because of a dull knife can double the life of your cutter. When the amperage is at a peak on the cut it is time to change the blade. When your cutter is cutting paper the average amp draw is 9 amps, as the blade becomes dull the motor works harder to get the blade through the paper. This puts a great deal of extra force on the motor shortening its life. Knowing when to change the blade doubles the life of the cut motor. When the amperage draw hits 14 amps it is time to change the blade.
|
IR Safety Wall Control Board Please match your board up exactly with the photograph. Different manufacture's of the same item name use different boards. Even the same manufacturer's use different boards as the machine develops. Example: Last years board may be different from this years board for the same machine. If the machine name matches but the board is different contact us. We probably have it in stock. We have no return on electronic parts.
|
Main PCI Control Board for 450VS+ WD model Please match your board up exactly with the photograph. Different manufacture's of the same item name use different boards. Even the same manufacturer's use different boards as the machine develops. Example: Last years board may be different from this years board for the same machine. If the machine name matches but the board is different contact us. We probably have it in stock. We have no return on electronic parts.
|
|
|
|
|
|
|
|
|
|
|
|
|
Main PCI Control Board for 450
|
Main PCI Control Board for 450V+ DC AC Please match your board up exactly with the photograph. Different manufacture's of the same item name use different boards. Even the same manufacturer's use different boards as the machine develops. Example: Last years board may be different from this years board for the same machine. If the machine name matches but the board is different contact us. We probably have it in stock. We have no return on electronic parts.
|
Main PCI Control Board for 4606S Please match your board up exactly with the photograph. Different manufacture's of the same item name use different boards. Even the same manufacturer's use different boards as the machine develops. Example: Last years board may be different from this years board for the same machine. If the machine name matches but the board is different contact us. We probably have it in stock. We have no return on electronic parts.
|
|
|
|
|
|
|
|
|
|
|
|
|
Main PCI Control Board for 4806K Please match your board up exactly with the photograph.
Different manufacture's of the same item name use different boards.
Even the same manufacturer's use different boards as the machine develops.
Example: Last years board may be different from this years board for the same machine.
If the machine name matches but the board is different contact us.
We probably have it in stock.
We have no return on electronic parts.
|
Main PCI Control Board for 4908S Please match your board up exactly with the photograph. Different manufacture's of the same item name use different boards. Even the same manufacturer's use different boards as the machine develops. Example: Last years board may be different from this years board for the same machine. If the machine name matches but the board is different contact us. We probably have it in stock. We have no return on electronic parts.
|
Main PCI Control Board for 4908M Please match your board up exactly with the photograph. Different manufacture's of the same item name use different boards. Even the same manufacturer's use different boards as the machine develops. Example: Last years board may be different from this years board for the same machine. If the machine name matches but the board is different contact us. We probably have it in stock. We have no return on electronic parts.
|
|